RIELLO
WHATSAPP:+08613761094501
E-MAIL:pittsenli@gmail.com
  • Home
  • About Us
    • About Us
    • Mission
    • R&D Center
    • History
  • Burner
  • Selection
  • Parts
  • Case
  • After service
  • Company
    • Company news
    • Industry News
  • Contact
Riello - Global burner leader brand > Company Information > 行业新闻

行业新闻


Correct spacing and height for flame detector installation


1. When installing point-type flame detectors on the ceiling of an inner corridor with a width of less than 3m, it is advisable to arrange them in the center. The installation spacing of temperature-sensitive fire detectors should not exceed 10m; the installation spacing of smoke-sensitive fire detectors should not exceed 15m; the distance from the detector to the end wall should not be greater than 1/2 of the detector installation spacing.


2. The horizontal distance from the flame detector to the wall or beam edge should not be less than 0.5m.


3. There should be no obstructions within 0.5m around the point-type flame detector.


4. When the room is divided by bookshelves, equipment or partitions, and the distance from the top to the ceiling or beam is less than 5% of the net height of the room, at least one point-type flame detector should be installed for each separated part.


5. The horizontal distance from the flame detector to the edge of the air supply outlet of the air conditioner should not be less than 1.5m, and it should be installed close to the return air outlet. The horizontal distance from the detector to the multi-hole air supply ceiling opening should not be less than 0.5m.


  • What is the difference between three-pass and two-pass boilers
  • What kind of dual-fuel burner should you choose for a 4-ton boiler
  • Common Riello Burner Controller Models
  • Requirements for Pollutant Emissions and Treatment in Waste-to-Energy Incinerati
  • How to Choose Industrial Burners to Meet Industrial Production Needs
  • Four aspects to consider when choosing the power of an electric boiler
  • What to do if the boiler burner fails to start
  • Boiler burner flame temperature
  • How to Install a Pressure Regulating Valve for a Boiler Burner
  • How to Clean a Boiler Burner

Back

Correct spacing and height for flame detector installation


1. When installing point-type flame detectors on the ceiling of an inner corridor with a width of less than 3m, it is advisable to arrange them in the center. The installation spacing of temperature-sensitive fire detectors should not exceed 10m; the installation spacing of smoke-sensitive fire detectors should not exceed 15m; the distance from the detector to the end wall should not be greater than 1/2 of the detector installation spacing.


2. The horizontal distance from the flame detector to the wall or beam edge should not be less than 0.5m.


3. There should be no obstructions within 0.5m around the point-type flame detector.


4. When the room is divided by bookshelves, equipment or partitions, and the distance from the top to the ceiling or beam is less than 5% of the net height of the room, at least one point-type flame detector should be installed for each separated part.


5. The horizontal distance from the flame detector to the edge of the air supply outlet of the air conditioner should not be less than 1.5m, and it should be installed close to the return air outlet. The horizontal distance from the detector to the multi-hole air supply ceiling opening should not be less than 0.5m.


RIELLO

Shanghai Qigu Technology Co., LTD
Block I-J, 14th Floor, Greenland Kechuang Building, 201 Ningxia Road, Putuo District, Shanghai
CHINA China,200333
Burner:Contact +08613761094501
Boiler:Contact +08613761094501
Fax :+08613761094501
E-mail:pittsenli@gmail.com


© Qigu Technology – copyright


Navigation

About Us
Burner
Low nitrogen burner
High temperature burner
Special burner
After service
Company
Contact

Networks

International
België/Belgique (Belgium)
Canada
中国 (China)
Hrvatska (Croatia)
Česká Republika (Czech Republic)
France (France)
Deutschland (Germany)
Magyarország (Hungary)
Italia (Italy)
Latvija (Latvia)
Polska (Poland)
România (Romania)
Россия (Russia)
España (Spain)
Slovenija (Slovenia)
United Kingdom
United States

Link

  • riello spare parts
  • plc control cabinets
  • 空压机配件
  • 电气控制柜
  • 利雅路燃烧器