How to deal with flameout failure


(1) When the riello burner is burning during normal operation, if the fire suddenly goes out, it is a flameout failure.


(2) After the unstable gas source causes flame fluctuations, extinguish the fire and deal with it; adjust the pressure and restart.


(3) When the flame detector malfunctions, the flame detection probe is grounded, or when it is too dirty, it cannot detect a normal flame and flameout occurs. Treatment method: adjust the probe position and clean the probe surface. Restart.


(4) Circuit failure, unstable power supply or lack of phase, causing flameout during the process. Solution: Contact an electrician to check the power supply and wiring. The burner does not start. The burner does not start when the start button is pressed for a long time: 1. External cascading failure. The external temperature or pressure control does not reach the lower starting limit; check the temperature or pressure setting value. 2. The internal chain of the burner does not pass. When the air pressure is too high or too low, when the air pressure switch is normally closed but not closed, or when the air door mechanism is not in place, it will all appear. Check it step by step. 3. The program controller fault has not been reset. Please reset it again.


(5) Fan motor overheat protection, reset the thermal relay.


(6) Check whether the start button of the control cabinet is normal.


  • Burner system fault detection method
  • Exhaust Gas Treatment for the Main Incineration Processes of Different Incinerat
  • Various Types of "Air" in Pulverized Coal Boiler Burners
  • Components of a Pure Oxygen Combustion System
  • Industrial Gas Burner Safety Operating Procedures introduce
  • Available Flue Gas Waste Heat Utilization Options
  • Analysis of Factors Affecting Boiler Thermal Efficiency
  • Intelligent Combustion Control Technology for Waste Incinerators
  • A Brief Discussion on "Air Preheater Cold-End Integrated Temperature"
  • What You Need to Know About Burner Selection

Back

How to deal with flameout failure


(1) When the riello burner is burning during normal operation, if the fire suddenly goes out, it is a flameout failure.


(2) After the unstable gas source causes flame fluctuations, extinguish the fire and deal with it; adjust the pressure and restart.


(3) When the flame detector malfunctions, the flame detection probe is grounded, or when it is too dirty, it cannot detect a normal flame and flameout occurs. Treatment method: adjust the probe position and clean the probe surface. Restart.


(4) Circuit failure, unstable power supply or lack of phase, causing flameout during the process. Solution: Contact an electrician to check the power supply and wiring. The burner does not start. The burner does not start when the start button is pressed for a long time: 1. External cascading failure. The external temperature or pressure control does not reach the lower starting limit; check the temperature or pressure setting value. 2. The internal chain of the burner does not pass. When the air pressure is too high or too low, when the air pressure switch is normally closed but not closed, or when the air door mechanism is not in place, it will all appear. Check it step by step. 3. The program controller fault has not been reset. Please reset it again.


(5) Fan motor overheat protection, reset the thermal relay.


(6) Check whether the start button of the control cabinet is normal.


RIELLO

Shanghai Qigu Technology Co., LTD
Block I-J, 14th Floor, Greenland Kechuang Building, 201 Ningxia Road, Putuo District, Shanghai
CHINA China,200333
Burner:Contact +08613761094501
Boiler:Contact +08613761094501
Fax :+08613761094501
E-mail:pittsenli@gmail.com


© Qigu Technology – copyright


Navigation

About Us
Burner
Low nitrogen burner
High temperature burner
Special burner
After service
Company
Contact

Networks

International
België/Belgique (Belgium)
Canada
中国 (China)
Hrvatska (Croatia)
Česká Republika (Czech Republic)
France (France)
Deutschland (Germany)
Magyarország (Hungary)
Italia (Italy)
Latvija (Latvia)
Polska (Poland)
România (Romania)
Россия (Russia)
España (Spain)
Slovenija (Slovenia)
United Kingdom
United States

Link

  • riello spare parts
  • plc control cabinets
  • 空压机配件
  • 电气控制柜
  • 利雅路燃烧器