公司新闻


Correct maintenance method of boiler burner


Repair and maintenance of burner manufacturer's equipment. For oil-fired burners, it is required to clean the basket filter between the oil tank and the oil pump. Regular cleaning of the filter keeps the fuel going to the pump and reduces potential component failure. Also check the filter for signs of excessive wear or damage. Check the fuel pressure regulator or pressure relief valve to see if the lock nut surface on the adjustable bolt is clean and removable. If the surface of the screws and nuts is found to be dirty or rusted, the regulating valve should be repaired or replaced. A poorly maintained fuel regulator valve can cause burner obstruction.


       


In order to ensure the safety and normal use of the burner, the burner should be maintained and maintained regularly, and repaired in time when a failure occurs.




Check the oil pump to determine whether its sealing device is intact and whether the internal pressure can be kept stable, and replace damaged or leaking sealing elements. If hot oil is used, it is necessary to make sure that all oil pipes are well insulated; if there are long oil pipes in the oil circuit, it is necessary to check whether the installation route is suitable. Replace damaged and poorly insulated tubing. For burners fueled by natural gas, check the main gas supply regulator to make sure the line is intact. Do not adjust the regulating valve of the gas company. The gas company will assist in cleaning, maintaining and adjusting the regulating valve of the main gas source. If there is a sense wire, check it for damage.


       


For the repair and maintenance of the equipment of the gas burner manufacturer, if a "y" type filter is installed in front of the control valve, it should be cleaned carefully. Check the control regulating valve on the gas burner to see if the adjusting bolt is easy to adjust. Make sure all outlets and screens are not blocked. Check the gas pipe group to confirm whether the manual switch adjustment is sensitive and whether the valve handle is installed. Check to see if the barometer is working properly. Accurate pressure display is critical when adjusting gas burners. The connection of the air valve needs to be cleaned and lubricated. If the connection is sticky or too rough, it needs to be replaced with a suitable fitting. If the burner is installed with detachable pipelines, care should also be taken to clean them.




Oil and gas burners have a wide range of applications, and burners are required in industrial occasions that need to burn fuel to heat materials or react. The burner, also known as the integrated burner, mainly uses fuel oil and gas. It is generally used in small and medium-sized fuel boilers, fuel hot air blowers, baking (baking) boxes and small fuel heating furnaces. After adding configuration, the function of the burner can be realized, but the burner cannot meet the requirements of fuel combustion heating or reaction in many industrial occasions. . See the entry for the difference between the two.


  • Working principle of RTO burner waste gas treatment equipment
  • What factors should be considered when selecting a linear burner
  • Causes and solutions for RTO burner flameout
  • Safety control requirements for boiler gas burners
  • Gas boiler water treatment problem solution
  • What to do if the burner does not ignite
  • Riello burners should be selected according to gas pressure
  • Conditions for shutdown of boiler due to accident
  • What tools are there for boiler burners
  • How to use the burner igniter

Back

Correct maintenance method of boiler burner


Repair and maintenance of burner manufacturer's equipment. For oil-fired burners, it is required to clean the basket filter between the oil tank and the oil pump. Regular cleaning of the filter keeps the fuel going to the pump and reduces potential component failure. Also check the filter for signs of excessive wear or damage. Check the fuel pressure regulator or pressure relief valve to see if the lock nut surface on the adjustable bolt is clean and removable. If the surface of the screws and nuts is found to be dirty or rusted, the regulating valve should be repaired or replaced. A poorly maintained fuel regulator valve can cause burner obstruction.


       


In order to ensure the safety and normal use of the burner, the burner should be maintained and maintained regularly, and repaired in time when a failure occurs.




Check the oil pump to determine whether its sealing device is intact and whether the internal pressure can be kept stable, and replace damaged or leaking sealing elements. If hot oil is used, it is necessary to make sure that all oil pipes are well insulated; if there are long oil pipes in the oil circuit, it is necessary to check whether the installation route is suitable. Replace damaged and poorly insulated tubing. For burners fueled by natural gas, check the main gas supply regulator to make sure the line is intact. Do not adjust the regulating valve of the gas company. The gas company will assist in cleaning, maintaining and adjusting the regulating valve of the main gas source. If there is a sense wire, check it for damage.


       


For the repair and maintenance of the equipment of the gas burner manufacturer, if a "y" type filter is installed in front of the control valve, it should be cleaned carefully. Check the control regulating valve on the gas burner to see if the adjusting bolt is easy to adjust. Make sure all outlets and screens are not blocked. Check the gas pipe group to confirm whether the manual switch adjustment is sensitive and whether the valve handle is installed. Check to see if the barometer is working properly. Accurate pressure display is critical when adjusting gas burners. The connection of the air valve needs to be cleaned and lubricated. If the connection is sticky or too rough, it needs to be replaced with a suitable fitting. If the burner is installed with detachable pipelines, care should also be taken to clean them.




Oil and gas burners have a wide range of applications, and burners are required in industrial occasions that need to burn fuel to heat materials or react. The burner, also known as the integrated burner, mainly uses fuel oil and gas. It is generally used in small and medium-sized fuel boilers, fuel hot air blowers, baking (baking) boxes and small fuel heating furnaces. After adding configuration, the function of the burner can be realized, but the burner cannot meet the requirements of fuel combustion heating or reaction in many industrial occasions. . See the entry for the difference between the two.


RIELLO

Shanghai Qigu Technology Co., LTD
Block I-J, 14th Floor, Greenland Kechuang Building, 201 Ningxia Road, Putuo District, Shanghai
CHINA China,200333
Burner:Contact +08613761094501
Boiler:Contact +08613761094501
Fax :+08613761094501
E-mail:pittsenli@gmail.com


© Qigu Technology – copyright


Navigation

About Us
Burner
Low nitrogen burner
High temperature burner
Special burner
After service
Company
Contact

Networks

International
België/Belgique (Belgium)
Canada
中国 (China)
Hrvatska (Croatia)
Česká Republika (Czech Republic)
France (France)
Deutschland (Germany)
Magyarország (Hungary)
Italia (Italy)
Latvija (Latvia)
Polska (Poland)
România (Romania)
Россия (Russia)
España (Spain)
Slovenija (Slovenia)
United Kingdom
United States

Link

  • riello spare parts
  • plc control cabinets
  • 空压机配件
  • 电气控制柜
  • 利雅路燃烧器